ILNAS-EN 60079-13:2017 Edition 10/2017
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
  •   
  •  
  • 53.4 / copy
  •  
 

Abstract

IEC 60079-13:2017(E) gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment by pressurization or artificial ventilation or both as applicable when located in an explosive gas atmosphere or combustible dust atmosphere hazardous area with or without an internal source of a flammable gas or vapour. It also includes a room located in a non-hazardous area that has an internal source of release of a flammable gas or vapour. This document deals with rooms that are partially constructed in a manufacturer’s facility and intended to have the final installation completed on-site, as well as rooms that are constructed completely on-site. Rooms partially constructed in a manufacturer’s facility may include third-party verification. For rooms built on-site, this document can be used by plant operators as a guide for assessment of those facilities. This document represents a major technical revision of the requirements for equipment protection by pressurized room "p" and artificially ventilated room "v" and should be considered as introducing all new requirements. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision.  This edition includes the following significant technical changes with respect to the previous edition: - modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p"; - addition of types of protection "pb", "pc", and "vc" and removal of types of protection "px", "py", "pz" and "pv"; - definition of the differences between pressurization and artificial ventilation types of protection; - removal of protection of rooms with an inert gas or a flammable gas from the scope of this document; - addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines. Additional information regarding the scope of this document can be found in Clause 1.

Status

Standard - Active

Origin

Technical Committee :
CLC/TC 31 : Electrical apparatus for potentially explosive atmospheres

Implementation

start of the vote on the project    15/08/2014   date of ratification (dor)    26/06/2017
end of the vote on the project    21/11/2014   date of anouncement (doa)    06/01/2018
start of the vote on the final project    03/03/2017   date of publication (dop)    06/04/2018
end of the vote on the final project    14/04/2017   date of withdrawal (dow)    06/10/2020


Publication Official Journal
of the Grand-Duchy of Luxembourg
01/02/2018
Reference Mémorial A N° 106

Relations

Evolutions

Relations to older standards
ILNAS-EN 60079-13:2010

Relations to international standards
IEC 60079-13 (31/1129/CDV) (EQV) 
IEC 60079-13 (31/1129/CDV) (EQV) 
IEC 60079-13 (31/1129/CDV) (EQV) 
IEC 60079-13 (31/1129/CDV) (EQV) 
IEC 60079-13:201X (31/1309/FDIS) (EQV) 
IEC 60079-13:2017 (EQV) 
IEC 60079-13:2017 

International Classification for Standards (ICS codes) :

29.260.20 : Electrical apparatus for explosive atmospheres