ILNAS-EN IEC 61280-4-5:2020 Edition 09/2020
Fibre-optic communication subsystem test procedures - Part 4-5: Installed cabling plant - Attenuation measurement of MPO terminated fibre optic cabling plant using test equipment with MPO interfaces
  •   
  •  
  • 83.8 / copy
  •  
 

Abstract

IEC 61280-4-5: 2020 is applicable to the measurement of attenuation and determination of polarity and length of installed multimode and single-mode optical fibre cabling plant, terminated with MPO connectors, using test equipment having an MPO interface. This cabling plant can include multimode or single-mode optical fibres, connectors, adapters, splices, and other passive devices. The cabling can be installed in a variety of environments including residential, commercial, industrial, and data centre premises, as well as outside plant environments. In this document, the optical fibres that are addressed include sub-categories A1-OMx, where x = 2, 3, 4 and 5 (50/125 μm) multimode optical fibres, as specified in IEC 60793-2-10, and category B-652 and B-657 (9/125 μm) single-mode optical fibres, as specified in IEC 60793-2-50. The attenuation measurements of the other multimode and single-mode categories can also be made using a light source and power meter (LSPM) or optical time domain reflectometer (OTDR) utilising an internal or external optical switch having one MPO interface. Multimode measurements are made with an 850 nm source because transceivers used for parallel optics applications having an MPO interface only operate at 850 nm; 1 300 nm measurements are optional. Single-mode measurements are made with a 1 310 nm and/or 1 550 nm source because transceivers used for parallel optics applications having an MPO interface operate at these wavelengths. This document does not include descriptions of cabling that is not exclusively MPO to MPO.

Status

Standard - Active

Origin

Technical Committee :
CLC/SR 86C : Fibre optic systems and active devices

Implementation

start of the vote on the project    10/01/2020   date of ratification (dor)    26/08/2020
end of the vote on the project    03/04/2020   date of anouncement (doa)    26/11/2020
start of the vote on the final project    22/05/2020   date of publication (dop)    26/05/2021
end of the vote on the final project    03/07/2020   date of withdrawal (dow)    26/08/2023


Publication Official Journal
of the Grand-Duchy of Luxembourg
26/03/2021
Reference Mémorial A N° 246

Relations

Evolutions
ILNAS-EN IEC 61280-4-5:2020/AC:2022-02

Relations to international standards
IEC 61280-4-5:202X 
IEC 61280-4-5:2020 
IEC 61280-4-5:201X 

International Classification for Standards (ICS codes) :

33.180.01 : Fibre optic systems in general