ILNAS-EN 12101-13:2022 Edition 04/2022
Smoke and heat control systems - Part 13: Pressure differential systems (PDS) - Design and calculation methods, installation, acceptance testing, routine testing and maintenance
  •   
  •   
  •   
  •  
  • 122.9 / copy
  •  
 

Abstract

This document gives calculation methods, guidance and requirements for the design, installation, acceptance testing, routine testing and maintenance for pressure differential systems (PDS). PDSs are designed to hold back smoke at a leaky physical barrier in a building, such as a door (either open or closed) or other similarly restricted openings and to keep tenable conditions in escape and access routes depending on the application. It covers systems intended to protect means of escape e.g. staircases, corridors, lobbies, as well as systems intended to provide a protected firefighting space (bridgehead) for the fire services. It provides details on the critical features and relevant procedures for the installation. It describes the commissioning procedures and acceptance testing criteria required to confirm that the calculated design is achieved in the building. This document gives rules, requirements and procedures to design PDS for buildings up to 60 m. For buildings taller than 60 m the same requirements are given (e.g. Table 1), but additional methods of calculation and verification are necessary. Requirements for such methods and verification are given in Annex D, but the methods fall outside the scope of this document [e.g. Additional mathematical analysis and/or Computational Fluid Dynamics (CFD)]. Routine testing and maintenance requirements are also defined in this document. In the absence of national requirements and under expected ambient and outside conditions, the requirements in Table 1 are fulfilled by the PDS.

Status

Standard - Active

Origin

Technical Committee :
CEN/TC 191 : Fixed firefighting systems

Implementation

start of the vote on the project    02/07/2020   date of ratification (dor)    14/02/2022
end of the vote on the project    24/09/2020   date of anouncement (doa)    31/07/2022
start of the vote on the final project    18/11/2021   date of publication (dop)    31/10/2022
end of the vote on the final project    13/01/2022   date of withdrawal (dow)    31/10/2022


Publication Official Journal
of the Grand-Duchy of Luxembourg
18/10/2022
Reference Mémorial A N° 521

Relations

Relations to older standards
ILNAS-EN 12101-6:2005
ILNAS-EN 12101-6:2005/AC:2006

International Classification for Standards (ICS codes) :

13.220.99 : Other standards related to protection against fire