ILNAS-EN 15269-3:2022 Edition 11/2022
Extended application of test results for fire resistance and/or smoke control for doorsets, shutter and openable window assemblies, including their elements of building hardware - Part 3: Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows
  •   
  •   
  •   
  •  
  • 136.7 / copy
  •  
 

Abstract

This document covers hinged or pivoted doorsets and door assemblies with wood-based door leaves and/or timber framed glazed door leaves and openable timber framed windows. Throughout this document, the term “doorset” will be used to cover doorsets, door assemblies and openable windows. It prescribes the rules for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1. This document covers only doorsets with wood-based or metal frames. The door leaves are comprised of wood-based perimeter framing and wood-based structural facings. Subject to the completion of the appropriate test or tests, the extended application can cover all or some of the following examples: - integrity (E), integrity & radiation (EW) or integrity & insulation (EI1 or EI2) classifications; - glazing within the doorset, e.g. side and over panels, vision panels and framed glazed doorsets; - air transfer grilles (e.g. ventilation grilles/louvres); - side, transom or over panels; - items of building hardware; - decorative and protective finishes; - intumescent strips and non-intumescent seals (e.g. smoke, draught or acoustic seals); - alternative supporting construction(s). This document covers only the effect on the fire resistance classifications E, EW, EI1 and EI2. This document does not cover horizontal doorsets.

Status

Standard - Active

Origin

Technical Committee :
CEN/TC 127 : Fire safety in buildings

Implementation

start of the vote on the project    15/10/2020   date of ratification (dor)    19/09/2022
end of the vote on the project    07/01/2021   date of anouncement (doa)    28/02/2023
start of the vote on the final project    23/06/2022   date of publication (dop)    31/05/2023
end of the vote on the final project    18/08/2022   date of withdrawal (dow)    31/05/2023


Publication Official Journal
of the Grand-Duchy of Luxembourg
23/05/2023
Reference Mémorial A N° 250

Relations

Relations to older standards
ILNAS-EN 15269-3:2012

International Classification for Standards (ICS codes) :

13.220.50 : Fire-resistance of building materials and elements
91.060.50 : Doors and windows