magnifying icon Basket
1 item ^

Basket is empty
Login

Login

LOGGED AS

Help

Satisfaction enquiry

SATISFACTION ENQUIRY

Newsletter

Free of charge lifelong learning "Standardization"

FREE OF CHARGE LIFELONG LEARNING "STANDARDIZATION"

Standardisation

Draft standards in public enquiry

DRAFT STANDARDS IN PUBLIC ENQUIRY

Standards organizations

STANDARDS ORGANIZATIONS

  • National standards

  • European standards

  • International standards


Deliverable

 
Free preview
Price
Language
 
ILNAS-EN 50122-3:2022 Edition 09/2022
Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 3: Mutual Interaction of AC and DC traction systems
  •   
  •   
  •  
  • 44.7 / copy
  •  
 

Abstract

This document specifies requirements for the protective provisions relating to electrical safety in fixed installations, when it is reasonably likely that hazardous voltages or currents will arise for people or equipment, as a result of the mutual interaction of AC and DC electric power supply traction systems. It also applies to all aspects of fixed installations that are necessary to ensure electrical safety during maintenance work within electric power supply traction systems. The mutual interaction can be of any of the following kinds: — parallel running of AC and DC electric traction power supply systems; — crossing of AC and DC electric traction power supply systems; — shared use of tracks, buildings or other structures; — system separation sections between AC and DC electric traction power supply systems. The scope is limited to galvanic, inductive and capacitive coupling of the fundamental frequency voltages and currents and their superposition. This document applies to all new lines, extensions and to all major revisions to existing lines for the following electric traction power supply systems: a) railways; b) guided mass transport systems such as: 1) tramways, 2) elevated and underground railways, 3) mountain railways, 4) magnetically levitated systems, which use a contact line system, 5) trolleybus systems, and 6) electric traction power supply systems for road vehicles, which use an overhead contact line system; c) material transportation systems. The document does not apply to: a) electric traction power supply systems in underground mines; b) cranes, transportable platforms and similar transportation equipment on rails, temporary structures (e.g. exhibition structures) in so far as these are not supplied directly or via transformers from the contact line system and are not endangered by the electric traction power supply system for railways; c) suspended cable cars; d) funicular railways; e) procedures or rules for maintenance. The rules given in this document can also be applied to mutual interaction with non-electrified tracks, if hazardous voltages or currents can arise from AC or DC electric traction power supply systems.

Status

Standard - Active

Origin

Technical Committee :
CLC/TC 9X : Electrical and electronic applications for railways

Implementation

start of the vote on the project    27/11/2020   date of ratification (dor)    25/07/2022
end of the vote on the project    19/02/2021   date of anouncement (doa)    25/01/2023
start of the vote on the final project    22/04/2022   date of publication (dop)    25/07/2023
end of the vote on the final project    17/06/2022   date of withdrawal (dow)    25/07/2025


Publication Official Journal
of the Grand-Duchy of Luxembourg
20/03/2023
Reference Mémorial A N° 154

Relations

Evolutions
EN 50122-3:2022/prA1:2024

Relations to older standards
ILNAS-EN 50122-3:2010

International Classification for Standards (ICS codes) :

29.120.50 : Fuses and other overcurrent protection devices
29.280 : Electric traction equipment

magnifying icon Basket
1 item ^

Basket is empty


Warning:
DIN standards can be downloaded only once! After downloading, they are no longer available in the eLibrary.
Begin download?