ILNAS-EN 1999-1-4:2023 Edition 03/2023
Eurocode 9 - Design of aluminium structures - Part 1-4: Cold-formed structural sheeting
  •   
  •   
  •  
  • 91.8 / copy
  •  
 

Abstract

1.1 Scope of EN 1999-1-4 (1) EN 1999-1-4 gives design requirements for cold-formed trapezoidal aluminium sheeting. It applies to cold-formed aluminium products made from hot rolled or cold rolled sheet or strip that have been cold-formed by such processes as cold-rolled forming or press-breaking. NOTE 1 The rules in this part complement the rules in other parts of EN 1999-1. NOTE 2 The execution of aluminium structures made of cold-formed structures for roof, ceiling, floor and wall applications is covered in EN 1090-5. (2) EN 1999-1-4 gives methods for stressed-skin design using aluminium sheeting as a structural diaphragm. (3) EN 1999-1-4 does not apply to cold-formed aluminium profiles like C- and Z- profiles nor cold-formed and welded circular or rectangular hollow sections. (4) EN 1999-1-4 gives methods for design by calculation and for design assisted by testing. The methods for the design by calculation apply only within stated ranges of material properties and geometrical properties for which sufficient experience and test evidence is available. These limitations do not apply to design by testing. (5) EN 1999-1-4 does not cover load arrangement for loads during execution and maintenance. 1.2 Assumptions (1) For the design of new structures, EN 1999 is intended to be used, for direct application, together with EN 1990, EN 1991, EN 1992, EN 1993, EN 1994, EN 1995, EN 1997 and EN 1998. EN 1999 is intended to be used in conjunction with: - European Standards for construction products relevant for aluminium structures; - EN 1090-1, Execution of steel structures and aluminium structures - Part 1: Requirements for conformity assessment of structural components; - EN 1090-5, Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applications.

Status

Standard - Active

Origin

Technical Committee :
CEN/TC 250 : Structural Eurocodes

Implementation

start of the vote on the project    04/03/2021   date of ratification (dor)    02/01/2023
end of the vote on the project    24/06/2021   date of anouncement (doa)    30/06/2023
start of the vote on the final project    06/10/2022   date of publication (dop)    30/09/2027
end of the vote on the final project    01/12/2022   date of withdrawal (dow)    30/03/2028


Publication Official Journal
of the Grand-Duchy of Luxembourg
08/09/2023
Reference Mémorial A N° 572

Relations

Relations to older standards
ILNAS-EN 1999-1-4:2007/AC:2009
ILNAS-EN 1999-1-4:2007/A1:2011
ILNAS-EN 1999-1-4:2007

International Classification for Standards (ICS codes) :

91.010.30 : Technical aspects
91.080.17

magnifying icon Basket
1 item ^

Basket is empty


Warning:
DIN standards can be downloaded only once! After downloading, they are no longer available in the eLibrary.
Begin download?