ILNAS-EN ISO 15002:2024 Edition 03/2024
Flow control devices for connection to a medical gas supply system (ISO 15002:2023)
  •   
  •   
  •  
  • 36.2 / copy
  •  
 

Abstract

This document specifies requirements for flow control devices that can be connected by the user either directly, by means of a probe or a gas-specific connector, or indirectly by means of a low-pressure hose assembly conforming with ISO 5359 to: a)    a terminal unit conforming with ISO 9170-1 of a medical gas pipeline system conforming with ISO 7396-1:2016; b)    the pressure outlet of a regulator conforming with ISO 10524-1:2018; or c)    to the pressure outlet of a valve integrated pressure regulator (VIPR) conforming with ISO 10524-3 (see 5.2 gas inlets). This document applies to the following types of flow control devices (FCDs): a)    flowmeters; b)    flowgauge FCDs; and c)    fixed orifice FCDs. NOTE       Flow control devices that are classed as medical electrical equipment can be subject to additional requirements of IEC 60601-1. This document applies to flow control devices for the following gases: —    oxygen; —    oxygen 93 %; —    nitrous oxide; —    medical air; —    carbon dioxide; —    oxygen/nitrous oxide mixture 50/50 (% volume fraction); —    oxygen-enriched air; —    helium; —    xenon; and —    specified mixtures of the gases listed above. NOTE Flow control devices can be available for other gases. This document does not apply to flow control devices that are: a)    for use with gases for driving surgical tools; b)    an integral part of a regulator (see ISO 10524-1:2018); or c)           an integral part of a valve with integrated pressure regulator (VIPR) (see ISO 10524-3).

Status

Standard - Active

Origin

Technical Committee :
CEN/TC 215 : Respiratory and anaesthetic equipment

Implementation

start of the vote on the project    30/11/2023   date of ratification (dor)    23/03/2024
end of the vote on the project    22/02/2024   date of anouncement (doa)    30/06/2024
start of the vote on the final project    01/01/2025   date of publication (dop)    30/09/2024
end of the vote on the final project    26/02/2025   date of withdrawal (dow)    30/09/2024


Publication Official Journal
of the Grand-Duchy of Luxembourg
Reference

Relations

Relations to older standards
ILNAS-EN ISO 15002:2008/A1:2019
ILNAS-EN ISO 15002:2008

International Classification for Standards (ICS codes) :

11.040.10 : Anaesthetic, respiratory and reanimation equipment