magnifying icon Basket
1 item ^

Basket is empty
Login

Login

LOGGED AS

Help

Satisfaction enquiry

SATISFACTION ENQUIRY

Newsletter

Free of charge lifelong learning "Standardization"

FREE OF CHARGE LIFELONG LEARNING "STANDARDIZATION"

Standardisation

Draft standards in public enquiry

DRAFT STANDARDS IN PUBLIC ENQUIRY

Standards organizations

STANDARDS ORGANIZATIONS

  • National standards

  • European standards

  • International standards


Deliverable

 
Free preview
Price
Language
 
ILNAS-EN 1998-2:2005/A2:2011 Edition 09/2011
Eurocode 8: Design of structures for earthquake resistance - Part 2: Bridges
  •   
  •   
  •   
  •  
  • 14.5 / copy
  •  
 

Abstract

(1) The scope of Eurocode 8 is defined in EN 1998-1:2004, 1.1.1 and the scope of this Standard is defined in 1.1.1. Additional parts of Eurocode 8 are indicated in EN 1998-1:2004, 1.1.3. (2) Within the framework of the scope set forth in EN 1998-1:2004, this part of the Standard contains the particular Performance Requirements, Compliance Criteria and Application Rules applicable to the design of earthquake resistant bridges. (3) This Part primarily covers the seismic design of bridges in which the horizontal seismic actions are mainly resisted through bending of the piers or at the abutments; i.e. of bridges composed of vertical or nearly vertical pier systems supporting the traffic deck superstructure. It is also applicable to the seismic design of cable-stayed and arched bridges, although its provisions should not be considered as fully covering these cases. (4) Suspension bridges, timber and masonry bridges, moveable bridges and floating bridges are not included in the scope of this Part. (5) This Part contains only those provisions that, in addition to other relevant Eurocodes or relevant Parts of EN 1998, should be observed for the design of bridges in seismic regions. In cases of low seismicity, simplified design criteria may be established (see 2.3.7(1)). (6) The following topics are dealt with in the text of this Part: Basic requirements and Compliance Criteria, Seismic Action, Analysis, Strength Verification, Detailing. This Part also includes a special section on seismic isolation with provisions covering the application of this method of seismic protection to bridges. (7) Annex G contains rules for the calculation of capacity design effects. (8) Annex J contains rules regarding the variation of design properties of seismic isolator units and how such variation may be taken into account in design.

Status

Standard - Active

Origin

Technical Committee :
CEN/TC 250 : Structural Eurocodes

Implementation

start of the vote on the project      date of ratification (dor)    08/04/2011
end of the vote on the project      date of anouncement (doa)    31/12/2011
start of the vote on the final project    07/10/2010   date of publication (dop)    30/09/2012
end of the vote on the final project    07/03/2011   date of withdrawal (dow)    30/09/2012


Publication Official Journal
of the Grand-Duchy of Luxembourg
05/06/2013
Reference Mémorial A N° 92

Relations

Relations to older standards
ILNAS-EN 1998-2:2005

International Classification for Standards (ICS codes) :

91.120.25 : Seismic and vibration protection
93.040 : Bridge construction