magnifying icon Basket
1 item ^

Basket is empty
Login

Login

LOGGED AS

Help

Satisfaction enquiry

SATISFACTION ENQUIRY

Newsletter

Free of charge lifelong learning "Standardization"

FREE OF CHARGE LIFELONG LEARNING "STANDARDIZATION"

Standardisation

Draft standards in public enquiry

DRAFT STANDARDS IN PUBLIC ENQUIRY

Standards organizations

STANDARDS ORGANIZATIONS

  • National standards

  • European standards

  • International standards


Deliverable

 
Free preview
Price
Language
 
ILNAS-EN 50600-1:2012 Edition 11/2012
Information technology - Data centre facilities and infrastructures - Part 1: General concepts
  •   
  •   
  •   
  •  
  • 40 / copy
  •  
 

Abstract

This European Standard: a) details the issues to be addressed in a business risk and operating cost analysis enabling application of an appropriate classification of the data centre, b) defines the common aspects of data centres including terminology, parameters and reference models (functional elements and their accommodation) addressing both the size and complexity of their intended purpose, c) describes general aspects of the facilities and infrastructures required to support effective operation of telecommunications within data centres, d) specifies a classification system, based upon the key criteria of “availability”, “security” and “energy-efficiency” over the planned lifetime of the data centre, for the provision of effective facilities and infrastructure, e) describes the general design principles for data centres upon which the requirements of the EN 50600 series are based including symbols, labels, coding in drawings, quality assurance and education, The following topics are outside of the scope of this series of European Standards: 1) the selection of information technology and network telecommunications equipment, software and associated configuration issues are outside the scope of this European Standard; 2) safety and electromagnetic compatibility (EMC) requirements (covered by other standards and regulations. However, information given in this European Standard may be of assistance in meeting these standards and regulations). 1.2 Conformance For a data centre design to conform to this European Standard: a) a business risk analysis according to Clause 4 shall be done, b) an appropriate Availability Class in 6.2 shall be selected using a business risk analysis in Clause 4, c) an appropriate Protection Class in 6.3 shall be selected using a business risk analysis in Clause 4, d) an appropriate energy efficiency enablement level in 6.4 shall be selected, e) the general design principles in Annex A shall be applied.

Status

Standard - Superseded

Origin

Technical Committee :
CLC/TC 215 : Electrotechnical aspects of telecommunication equipment

Implementation

start of the vote on the project    02/12/2011   date of ratification (dor)   
end of the vote on the project    02/02/2012   date of anouncement (doa)    22/04/2013
start of the vote on the final project    13/07/2012   date of publication (dop)    22/10/2013
end of the vote on the final project    13/09/2012   date of withdrawal (dow)    22/10/2015


Publication Official Journal
of the Grand-Duchy of Luxembourg
05/06/2013
Reference

Relations

Evolutions
ILNAS-EN 50600-1:2019

International Classification for Standards (ICS codes) :

35.020 : Information technology (IT) in general
35.160 : Microprocessor systems

magnifying icon Basket
1 item ^

Basket is empty


Warning:
DIN standards can be downloaded only once! After downloading, they are no longer available in the eLibrary.
Begin download?