IEC 60287-1-2 Ed.2.0 Edition 05/2023
Electric cables - Calculation of the current rating - Part 1-2: Current rating equations (100 % load factor) and calculations of losses - Sheath eddy current loss factors for two circuits in flat formation
  •   
  •  
  • 191 / copy
  •  
 

Abstract

IEC 60287-1-2:2023 provides a method for calculating the eddy current losses in the metallic sheaths of single-core cables arranged as a three-phase double circuit in flat formation. The sheaths are bonded at one point or are cross-bonded so that there are no significant sheath circulating currents. Where metallic sheaths are bonded at both ends there are significant circulating currents which result in a lower current-carrying capacity. A method of calculating circulating current losses for double circuits is provided in IEC 60287-1-3.
The method descibed in this document provides coefficients which are applied as corrections to the loss factors for the sheaths of one isolated three-phase circuit. These corrections are negligible for cables where the parameter m is less than approximately 0,1 (m = ω/(Rs · 107)), which corresponds to a sheath longitudinal resistance higher than 314 µΩ/m at 50 Hz.
Consequently, the method is used for most sizes of aluminium-sheathed cables, but is not required for lead-sheathed cables unless they are unusually large.
The coefficients are provided in tabular form and have been computed from fundamental formulae for sheath losses, the evaluation of which calls for expertise in computer programming which will possibly not be readily available in general commercial situations. The development of simplified formulae for some of the tabulated coefficients is under consideration.
Losses for cables in a single circuit is covered in IEC 60287-1-1.

Status

Standard - Active

Origin

Technical Committee :
20 : Electric cables

Implementation

start of the vote on the project      date of ratification (dor)   
end of the vote on the project      date of anouncement (doa)   
start of the vote on the final project      date of publication (dop)   
end of the vote on the final project      date of withdrawal (dow)   


Publication Official Journal
of the Grand-Duchy of Luxembourg
Reference

Relations

Relations to older standards
IEC 60287-1-2 Ed. 1.0
IEC 60287-1-2 Ed. 1.0
IEC 60287-1-2 Ed. 1.0

International Classification for Standards (ICS codes) :