ILNAS-EN 50131-2-4:2020 Edition 08/2020
Alarm systems - Intrusion and hold-up systems - Part 2-4: Requirements for combined passive infrared and microwave detectors
  •   
  •   
  •  
  • 67.3 / copy
  •  
 

Abstract

This document is for combined passive infrared and microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This document does not include requirements for detectors intended for use outdoors. The purpose of the detector is to detect the broad spectrum infrared radiation emitted by an intruder, to emit microwave signals and analyse the signals that are returned and to provide the necessary range of signals or messages to be used by the rest of the intrusion alarm system. For a combined detector where both detection technologies need to be in their activated state in order to generate an alarm condition, the grade-dependent requirements of this document apply. For combined detectors which can be configured or operated such that each detection technology can generate an alarm condition independently, the grade-dependant requirements as defined in EN 50131 2 2 and EN 50131-2-3 apply, when configured accordingly. Otherwise, it is the responsibility of the manufacturer to clearly state that the detector does not comply to this document and not to EN 50131-2-2 and EN 50131 2-3 when put into such a configuration. It is essential that a detector fulfils all the requirements of the specified grade. Functions additional to the mandatory functions specified in this document can be included in the detector, providing they do not influence the correct operation of the mandatory functions. Requirements for system interconnections are not included in this document.

Status

Standard - Active

Origin

Technical Committee :
CLC/TC 79 : Alarm systems

Implementation

start of the vote on the project    05/07/2019   date of ratification (dor)    30/06/2020
end of the vote on the project    27/09/2019   date of anouncement (doa)    30/12/2020
start of the vote on the final project    03/04/2020   date of publication (dop)    30/06/2021
end of the vote on the final project    29/05/2020   date of withdrawal (dow)    30/06/2023


Publication Official Journal
of the Grand-Duchy of Luxembourg
23/02/2021
Reference Mémorial A N° 127

Relations

Relations to older standards
ILNAS-EN 50131-2-4:2008

International Classification for Standards (ICS codes) :

13.310 : Protection against crime