ILNAS-EN 14382:2005+A1:2009 Edition 03/2009
Safety devices for gas pressure regulating stations and installations - Gas safety shut-off devices for inlet pressures up to 100 bar
  •   
  •   
  •   
  •  
  • 83.8 / copy
  •  
 

Abstract

This document specifies constructional, functional, testing and marking requirements, sizing and documentation of gas safety shut-off devices used in the pressure regulating stations in accordance with EN 12186 or EN 12279: - for inlet pressures up to 100 bar and nominal diameters up to DN 400; - for an operating temperature range from -20 °C to +60 °C, which operate with fuel gases of the 1st and 2nd family in accordance with EN 437 in transmission and distribution networks and also in commercial and industrial installations. "Gas safety shut-off devices" will hereafter be called "SSDs" except in titles. For standard safety shut-off devices when used in pressure regulating stations complying with EN 12186 or EN 12279, Annex ZA lists all applicable Essential Requirements except the external corrosion resistance in case of environmental conditions where corrosion is likely to occur. This document considers the following classes/types of SSDs: temperature classes: - class 1: operating temperature range from -10 °C to 60 °C; - class 2: operating temperature range from -20 °C to 60 °C; functional classes: - class A: SSDs that close when damage to the pressure detector element occurs (applicable to overpressure SSDs only) or when external power fails and whose re-opening, after an intervention for overpressure, is possible only manually; - class B: SSDs that do not close when damage to the pressure detector element occurs and whose re-opening, after an intervention for overpressure, is possible only manually; SSDs types: - type IS: (integral strength type); - type DS: (differential strength type). SSDs complying with the requirements of this document may be declared as "in conformity with EN 14382" and bear the mark "EN 14382". The material and functional requirements specified in this document may be applied to SSDs which use thermal energy or the effects of electrical energy to trip the operation of the closing member. For these SSDs the operat

Status

Standard - Superseded

Origin

Technical Committee :
CEN/TC 235 : Gas pressure regulators and associated safety devices for use in gas transmission and distribution

Directives

97/23/EC : Pressure equipment

Implementation

start of the vote on the project      date of ratification (dor)    12/01/2009
end of the vote on the project      date of anouncement (doa)    30/06/2009
start of the vote on the final project      date of publication (dop)    30/09/2009
end of the vote on the final project      date of withdrawal (dow)    30/09/2009


Publication Official Journal
of the Grand-Duchy of Luxembourg
14/03/2012
Reference

Relations

Evolutions
ILNAS-EN 14382:2005+A1:2009/AC:2009
ILNAS-EN 14382:2019

Relations to older standards
ILNAS-EN 13787:2001
EN 14382:2005/prA1
ILNAS-EN 14382:2005

International Classification for Standards (ICS codes) :

23.060.40 : Pressure regulators