ILNAS-EN 14382:2005+A1:2009 Edition 03/2009
Dispositifs de sécurité pour postes et installations de détente-régulation de pression de gaz - Clapets de sécurité pour pressions amont jusqu'à 100 bar
  •   
  •   
  •   
  •  
  • 83.8 / exemplaire
  •  
 

Résumé

This document specifies constructional, functional, testing and marking requirements, sizing and documentation of gas safety shut-off devices used in the pressure regulating stations in accordance with EN 12186 or EN 12279: - for inlet pressures up to 100 bar and nominal diameters up to DN 400; - for an operating temperature range from -20 °C to +60 °C, which operate with fuel gases of the 1st and 2nd family in accordance with EN 437 in transmission and distribution networks and also in commercial and industrial installations. "Gas safety shut-off devices" will hereafter be called "SSDs" except in titles. For standard safety shut-off devices when used in pressure regulating stations complying with EN 12186 or EN 12279, Annex ZA lists all applicable Essential Requirements except the external corrosion resistance in case of environmental conditions where corrosion is likely to occur. This document considers the following classes/types of SSDs: temperature classes: - class 1: operating temperature range from -10 °C to 60 °C; - class 2: operating temperature range from -20 °C to 60 °C; functional classes: - class A: SSDs that close when damage to the pressure detector element occurs (applicable to overpressure SSDs only) or when external power fails and whose re-opening, after an intervention for overpressure, is possible only manually; - class B: SSDs that do not close when damage to the pressure detector element occurs and whose re-opening, after an intervention for overpressure, is possible only manually; SSDs types: - type IS: (integral strength type); - type DS: (differential strength type). SSDs complying with the requirements of this document may be declared as "in conformity with EN 14382" and bear the mark "EN 14382". The material and functional requirements specified in this document may be applied to SSDs which use thermal energy or the effects of electrical energy to trip the operation of the closing member. For these SSDs the operat

Statut

Standard - Remplacé

Origine

Comité technique :
CEN/TC 235 : Régulateurs de pression de gaz et dispositifs de sécurité associés pour le transport et la distribution de gaz

Directives

97/23/EC : Pressure equipment

Mise en application

début du vote sur le projet      date de ratification (dor)    12/01/2009
fin du vote sur le projet      date d'annonce (doa)    30/06/2009
début du vote sur le projet final      date de publication (dop)    30/09/2009
fin du vote sur le projet final      date de retrait (dow)    30/09/2009


Publication au Journal officiel
du Grand-Duché de Luxembourg
14/03/2012
Référence

Relations

Evolutions
ILNAS-EN 14382:2005+A1:2009/AC:2009
ILNAS-EN 14382:2019

Relations avec d'anciennes normes
ILNAS-EN 13787:2001
EN 14382:2005/prA1
ILNAS-EN 14382:2005

Classification internationale pour les normes (codes ICS) :

23.060.40 : Pressure regulators