ILNAS-EN 12845:2004+A2:2009 Edition 04/2009
Installations fixes de lutte contre l‘incendie - Systèmes d’extinction automatique du type sprinkleur - Conception, installation et maintenance
  •   
  •   
  •   
  •  
  • 122.9 / exemplaire
  •  
 

Résumé

This standard specifies requirements and gives recommendations for the design, installation and maintenance of fixed fire sprinkler systems in buildings and industrial plant, and particular requirements for sprinkler systems, which are integral to measures for the protection of life. This standard covers only the types of sprinkler specified in EN 12259-1 (see annex L). The requirements and recommendations of this standard are also applicable to any addition, extension, repair or other modification to a sprinkler system. They are not applicable to water spray or deluge systems. It covers the classification of hazards, provision of water supplies, components to be used, installation and testing of the system, maintenance, and the extension of existing systems, and identifies construction details of buildings which are the minimum necessary for satisfactory performance of sprinkler systems complying with this standard. This standard does not cover water supplies to systems other than sprinklers. Its requirements can be used as guidance for other fixed fire fighting extinguishing systems, however, provided that any specific requirements for other fire fighting extinguishing supplies are taken into account. The requirements are not valid for automatic sprinkler systems on ships, in aircraft, on vehicles and mobile fire appliances or for below ground systems in the mining industry. Sprinkler system design deviations may be allowed when such deviations have been shown to provide a level of protection at least equivalent to this European Standard, for example by means of full scale fire testing where appropriate, and where the design criteria have been fully documented.

Statut

Standard - Remplacé

Origine

Comité technique :
CEN/TC 191 : Installations fixes de lutte contre l'incendie

Mise en application

début du vote sur le projet      date de ratification (dor)    22/02/2009
fin du vote sur le projet      date d'annonce (doa)    31/07/2009
début du vote sur le projet final      date de publication (dop)    31/10/2009
fin du vote sur le projet final      date de retrait (dow)    31/10/2009


Publication au Journal officiel
du Grand-Duché de Luxembourg
14/03/2012
Référence

Relations

Evolutions
ILNAS-EN 12845:2015

Relations avec d'anciennes normes
EN 12845:2004/prA2
EN 12845:2004/prA1
ILNAS-EN 12845:2004

Classification internationale pour les normes (codes ICS) :

13.220.20 : Fire protection

magnifying icon Panier

Votre panier est vide


Attention:
Les normes DIN ne peuvent être téléchargées qu’une seule fois! Après le téléchargement, elles ne seront plus disponibles dans l’eBibliothèque.
Continuer avec le téléchargement?