ILNAS-EN ISO 80601-2-12:2023 Edition 11/2023
Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators (ISO 80601-2-12:2023)
  •   
  •   
  •  
  • 136.7 / copy
  •  
 

Abstract

This document applies to the basic safety and essential performance of a critical care ventilator in combination with its accessories, hereafter referred to as ME equipment: ¾     intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility; NOTE 2      For the purposes of this document, such an environment is referred to as a critical care environment. Ventilators for this environment are considered life-sustaining. NOTE 3      For the purposes of this document, such a critical care ventilator can provide ventilation during transport within a professional healthcare facility (i.e. be a transit-operable ventilator). NOTE 4      A critical care ventilator intended for use in transport within a professional healthcare facility is not considered as an emergency medical services environment ventilator. ¾     intended to be operated by a healthcare professional operator; and ¾     intended for those patients who need differing levels of support from artificial ventilation including for ventilator-dependent patients. A critical care ventilator is not considered to use a physiologic closed-loop-control system unless it uses a physiological patient variable to adjust the artificial ventilation therapy settings. This document is also applicable to those accessories intended by their manufacturer to be connected to a ventilator breathing system, or to a ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilator. NOTE 5     If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1. NOTE 6     Additional information can be found in IEC 60601-1:2005+AMD1:2012+AMD2:2020, 4.2. This document is not applicable to ME equipment or an ME system operating in a ventilator-operational mode solely intended for patients who are not dependent on artificial ventilation. NOTE 7     A critical care ventilator, when operating in such a ventilator-operational mode, is not considered life-sustaining. This document is not applicable to ME equipment that is intended solely to augment the ventilation of spontaneously breathing patients within a professional healthcare facility. This document does not specify the requirements for: NOTE 8     See ISO/TR 21954 for guidance on the selection of the appropriate ventilator for a given patient. ¾     ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601‑2‑13; ¾     ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601-2-84; ¾     ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601‑2-72; ¾     ventilators or accessories intended for home-care ventilatory support devices, which are given in ISO 80601-2-79 and ISO 80601-2-80; ¾     obstructive sleep a

Status

Standard - Active

Origin

Technical Committee :
CEN/TC 215 : Respiratory and anaesthetic equipment

Implementation

start of the vote on the project    05/08/2021   date of ratification (dor)    01/09/2023
end of the vote on the project    26/10/2021   date of anouncement (doa)    29/02/2024
start of the vote on the final project    08/06/2023   date of publication (dop)    31/05/2024
end of the vote on the final project    31/07/2023   date of withdrawal (dow)    31/05/2024


Publication Official Journal
of the Grand-Duchy of Luxembourg
Reference

Relations

Relations to older standards
ILNAS-EN ISO 80601-2-12:2020

Relations to international standards
ISO 80601-2-12 
ISO 80601-2-12:2023 

International Classification for Standards (ICS codes) :

11.040.10 : Anaesthetic, respiratory and reanimation equipment