magnifying icon Warenkorb

Der Warenkorb ist leer
Login

Login

ANGEMELDET ALS

Hilfe

Kundenumfrage

Newsletter

Kostenfreie weiterbildung "Normung"

KOSTENFREIE WEITERBILDUNG "NORMUNG"

Normung

Normen-Entwürfe

Normungsorganisationen

NORMUNGSORGANISATIONEN

  • Nationale Normen

  • Europäische Normen

  • Internationale Normen


Veröffentlichung

 
Kostenlose Vorschau
Gesamtbetrag
Sprache
 
ILNAS-EN IEC 60794-1-111:2023 Edition 10/2023
Lichtwellenleiterkabel - Teil 1-111: Fachgrundspezifikation - Grundlegende Prüfverfahren für Lichtwellenleiterkabel - Mechanische Prüfverfahren - Biegen, Verfahren E11
  •   
  •   
  •  
  • 34 / Kopie
  •  
 

Abstract

IEC 60794-1-111: 2023 defines the test procedure to determine the ability of an optical fibre cable to withstand bending around a test mandrel. The primary purpose of this procedure is to measure the change in attenuation when the cable is bent around a test mandrel. A secondary purpose is to assess whether the cable has been physically damaged by bending. NOTE 1 This test can be utilized at any specified temperature, including the low or high temperature limits for the cable. NOTE 2 The bend test procedure for cable elements is specified in IEC 60794-1-301, method G1. This document partially cancels and replaces IEC 60794-1-21:2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794‑1‑21:2015: a) the nominal sample length was newly specified as 10 m between the cable element fixing points at both ends, unless otherwise specified; b) the number of turns on the mandrel in Figure 1 for the single-helix configuration were corrected to match the number of turns shown in the figure for the two-helix configuration; c) requirements on the turnaround loop were added for method E11A, two-helix configuration; d) the turnaround loop with the same diameter as the mandrel was taken into account for calculation of the number of turns of each helix for method E11A, two-helix configuration; e) added a formula for calculation of the number of revolutions in each helix for method E11A, two-helix configuration; f) added a description for the procedure when the turnaround loop diameter is larger than the mandrel diameter for method E11A, two-helix configuration; g) all the figures were updated and the different components labelled; h) added the attenuation monitoring equipment in 4.2 for the apparatus and the description to measure the change in attenuation in the test methods E11A and E11B; i) added Clause 9 for details to be reported; j) added Annex A showing an example of a special mandrel to perform the bend test according to method E11A, two-helix configuration; k) added Annex B providing the rationale for the options of method E11A, two-helix configuration.

Status

Standard - Aktiv

Ursprung

Technisches Komitee :
CLC/TC 86A : Lichtwellenleiter (LWL) und LWL-Kabel

Annahme

Beginn der Abstimmung über den Entwurf    20/01/2023   Datum der Ratifizierung (dor)    24/10/2023
Ende der Abstimmung über den Entwurf    14/04/2023   Datum der Ankündigung (doa)    24/01/2024
Beginn der Abstimmung über den Schlussentwurf    01/04/2024   Datum der Veröffentlichung (dop)    24/07/2024
Ende der Abstimmung über den Schlussentwurf    13/05/2024   Datum der Zurückziehung (dow)    24/10/2026


Veröffentlichung im Amtsblatt
des Grossherzogtum Luxemburg
23/04/2024
Referenz Mémorial A N° 158

Relations

Relations to older standards
ILNAS-EN 60794-1-21:2015
ILNAS-EN 60794-1-21:2015/A1:2020

Entspricht der/den internationalen Norm(en)
IEC 60794-1-111 ED1 
IEC 60794-1-111:2023 

Internationale Normungsklassifizierung (ICS) :

33.180.10 : Fibres and cables

magnifying icon Warenkorb

Der Warenkorb ist leer


Achtung:
DIN-Normen können nur einmal heruntergeladen werden! Nach dem Herunterladen, sind sie nicht mehr in der eBibliothek verfügbar.
Download starten?