IEC 60695-2-11 Ed.2.0 Edition 02/2014
Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
  •  
  • 72.8 / Kopie
  •  
 

Abstract

IEC 60695-2-11:2014 specifies a test method on an end product. It is intended to simulate the effects of thermal stresses produced by an electrically heated source to represent a fire hazard. This test method is used to check that, under defined test conditions, an end product exposed to an electrically heated source has either a limited ability to ignite or, if it ignites, a limited ability to propagate flame. However, the fire hazard analysis, the flammability aspects and the flame spreading to otherproducts are not covered by the present standard. This second edition of IEC 60695-2-11 cancels and replaces the first edition of IEC 60695-2-11 published in 2000. It constitutes a technical revision. The main changes with respect to the previous edition are:
- the Introduction has been added to provide background and how it relates to the Scope,
- the Scope has been modified for greater clarity and reference to basic safety publications,
- numerous terms and definitions relevant to this Standard have been added to Clause 3,
- the application of "small parts" and "insignificant mass" have been introduced and clarified,
- the different types of specimens, how to specify them, and limitations of the test method have been further clarified in Clause 4,
- clarified in Clause 5 the distance to specified layer when unknown,
- the information from Clause 6 has been moved into the test procedure in Clause 8,
- the conditioning of the specified layer and the laboratory ambient test conditions were clarified in Clause 7,
- measurement of the maximum flame height was removed from Clause 9,
- the reference to this test as "GWEPT" was introduced along with an applicable title change and
- Annex A has been revised to reflect current practice by prominent product committees.
Key words: Glowing/hot-wire, Glow wire, Flammability, Fire hazard
This publication is to be read in conjunction with IEC 60695-2-10:2013.

Status

Standard - Ersetzt

Ursprung

Technisches Komitee :
89 : Fire hazard testing

Annahme

Beginn der Abstimmung über den Entwurf      Datum der Ratifizierung (dor)   
Ende der Abstimmung über den Entwurf      Datum der Ankündigung (doa)   
Beginn der Abstimmung über den Schlussentwurf      Datum der Veröffentlichung (dop)   
Ende der Abstimmung über den Schlussentwurf      Datum der Zurückziehung (dow)   


Veröffentlichung im Amtsblatt
des Grossherzogtum Luxemburg
Referenz

Relations

Evolutions
IEC 60951-3 Ed.3.0 RLV
IEC 60695-2-11 Ed.3.0

Relations to older standards
IEC 60695-2-11 Ed. 1.0

Internationale Normungsklassifizierung (ICS) :

13.220.40 : Ignitability and burning behaviour of materials and products
29.020 : Electrical engineering in general

magnifying icon Warenkorb

Der Warenkorb ist leer


Achtung:
DIN-Normen können nur einmal heruntergeladen werden! Nach dem Herunterladen, sind sie nicht mehr in der eBibliothek verfügbar.
Download starten?