magnifying icon Warenkorb

Der Warenkorb ist leer
Login

Login

ANGEMELDET ALS

Hilfe

Kundenumfrage

Newsletter

Kostenfreie weiterbildung "Normung"

KOSTENFREIE WEITERBILDUNG "NORMUNG"

Normung

Normen-Entwürfe

Normungsorganisationen

NORMUNGSORGANISATIONEN

  • Nationale Normen

  • Europäische Normen

  • Internationale Normen


Veröffentlichung

 
Kostenlose Vorschau
Gesamtbetrag
Sprache
 
IEC 61689 Ed.4.0 Edition 03/2022
Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz
  •   
  •  
  • 345.6 / Kopie
  •  
 

Abstract

IEC 61689:2022 is applicable to ultrasonic equipment designed for physiotherapy containing an ultrasonic transducer generating continuous or quasi-continuous (e.g. tone burst) wave ultrasound in the frequency range 0,5 MHz to 5 MHz. This document only relates to ultrasonic physiotherapy equipment employing a single plane non-focusing circular transducer per treatment head, producing static beams perpendicular to the face of the treatment head. This document specifies:
- methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on reference testing methods;
- characteristics to be specified by manufacturers of ultrasonic physiotherapy equipment based on reference testing methods;
- guidelines for safety of the ultrasonic field generated by ultrasonic physiotherapy equipment;
- methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on routine testing methods;
- acceptance criteria for aspects of the output of ultrasonic physiotherapy equipment based on routine testing methods.
Therapeutic value and methods of use of ultrasonic physiotherapy equipment are not within the scope of this document.
Ultrasonic physiotherapy equipment using ultrasound in the frequency range from 20 kHz to 500 kHz is dealt with in IEC 63009.
IEC 61689:2022 cancels and replaces the third edition published in 2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition.
a) The requirement on water oxygen content is specified in 6.1.
b) Former recommendations in 6.2 have been changed to become requirements.
c) Several definitions in Clause 3 have been updated in line with other TC 87 documents.
d) The formerly informative Annex A has been changed to become normative, and now contains details on how conformance with IEC 60601-2-5 requirements is checked.
e) Annex D has been considerably shortened and reference to a now withdrawn regulatory document has been removed.

Status

Standard - Aktiv

Ursprung

Technisches Komitee :
87 : Ultrasonics

Annahme

Beginn der Abstimmung über den Entwurf      Datum der Ratifizierung (dor)   
Ende der Abstimmung über den Entwurf      Datum der Ankündigung (doa)   
Beginn der Abstimmung über den Schlussentwurf      Datum der Veröffentlichung (dop)   
Ende der Abstimmung über den Schlussentwurf      Datum der Zurückziehung (dow)   


Veröffentlichung im Amtsblatt
des Grossherzogtum Luxemburg
Referenz

Relations

Relations to older standards
IEC 61689 Ed. 3.0

Internationale Normungsklassifizierung (ICS) :

11.040.60 : Therapy equipment

magnifying icon Warenkorb

Der Warenkorb ist leer


Achtung:
DIN-Normen können nur einmal heruntergeladen werden! Nach dem Herunterladen, sind sie nicht mehr in der eBibliothek verfügbar.
Download starten?